1. due to the curing of two-component sealant needs a certain period of time, therefore, the glass has been coated with two-component sealant should be gently moved.
Group 2.A and group B should be kept clean and prevent foreign matter from entering the glue.
3., in the continuous work process, glue gun every time to stop work, usually not more than 20 minutes, otherwise, use A group glue out of all the mixing glue, until a single A component glue from the gun discharge.
4. high-pressure hose shall not be forced extrusion and bending to prevent the normal operation of the system.
5., mixing glue should always keep smooth, in order to ensure good adhesive effect. In case of blockage, acetone can be soaked and cleaned. It is recommended that every 5 groups be washed once.
6. when the glue gun is not used for a long time (more than one week), the gun body should be removed. The residual colloid in the glue gun and mixing glue shall be cleaned with solvent.
7., different parts of the production of adhesive gum manufacturers contain different amounts of impurities, according to the actual situation, clear B components of the filter and one-way check valve, it is recommended that every two groups of cleaning.
8. any gel gun, pipe or machine failure caused by colloid solidification will not be within the scope of warranty.
9. regular refueling pump to the mouth, should ensure that the oil mist constantly oil.