1、 Environmental requirements:
1. To meet the environmental management material content standards of customers, to avoid environmental pollution and harm to human health. 2. Ensure the company's better sustainable operation and development.
2、 Precautions before operation:
1. The charging fan operates normally, there is no debris on the charging table, and the power supply voltage indication can be started within 380V ± 10%. 2. The intensity switch must be turned off after discharging, and live operation is strictly prohibited. 3. It is not necessary to discharge when it is turned off after work
4. After discharge, the machine can not be started again. Only when the power supply is cut off again, the machine can be started. Only when the magnetizing voltage reaches above 1.2KV, the machine can be magnetized
1. Turn on the power switch (including the ground switch), the power indicator light will be on and the power voltage meter will display the power voltage
2. Press the power on button, the magnetization indicator light will be on and the magnetization voltmeter will display the magnetization voltage
3. Put the magnetizing mold of the loaded object into the filling head, press the filled object with a special rod, and press the foot switch OK. Remove the magnetized object from the mold, and put it into the plastic basin or wooden board to separate it from the filled object
4、 Quality requirements and precautions:
1. Do not reverse the magnetic charge or deform the bracket
2. Do not mix the charged and charged magnets